Xylem Expert 800-900 Manuale Utente

Navigare online o scaricare Manuale Utente per Apparecchiature Xylem Expert 800-900. Xylem Expert 800-900 User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa

Sommario

Pagina 1 - Expert Level Loggers

ManualGB Manual Expert Log 800-900.doc1MJK800 / 900 LogExpert Level Loggers

Pagina 2 - Dear Customer

ManualGB Manual Expert Log 800-900.doc10Under Install Type, you may choose the type of installation:Typical and Compact: Default instal

Pagina 3

ManualGB Manual Expert Log 800-900.doc11Finally, you can specify the ProgramFolder to be created under Programs in the Start menu.* Non-water level ap

Pagina 4 - Measuring methods

ManualGB Manual Expert Log 800-900.doc12The configuration program (Writer / WriterWL)These programs are used for the configuration and starting/stoppi

Pagina 5 - Installation

ManualGB Manual Expert Log 800-900.doc13InitializationThe Expert Log needs to be initialized before communication can be established with it. This can

Pagina 6 - Seeger circlip

ManualGB Manual Expert Log 800-900.doc14To reset a sensor to its factory setting, click Set Factory Zero respectively.To update the pressure values di

Pagina 7 - Caution:

ManualGB Manual Expert Log 800-900.doc15Configuration function sChannels to recordHere, the channels to record are selected by checking off the corre

Pagina 8 - Dip pipe installation

ManualGB Manual Expert Log 800-900.doc16Building Mean value after X measurements at 1 second intervalsThis function enables the averaging over "X

Pagina 9 - Installation of the software

ManualGB Manual Expert Log 800-900.doc17Save if delta Channel > Val1Recording only takes place if the measured value of the channel where event-dri

Pagina 10 - Files installed

ManualGB Manual Expert Log 800-900.doc18Val1Endless (circular memory)This function is enabled by the user for continuous recording by the device. That

Pagina 11

ManualGB Manual Expert Log 800-900.doc19Actual valueIf the Online function is activated by clicking Online, this field displays the current value of t

Pagina 12 - WriterWL

ManualGB Manual Expert Log 800-900.doc2Dear Customer,Congratulations on your purchase of MJK Expert Data Loggers, thenext generation Data Logger!Befor

Pagina 13 - The menus

ManualGB Manual Expert Log 800-900.doc20Offset:-Offset is a freely selectable value (positive or negative) which is added to the lengthcalculated. The

Pagina 14

ManualGB Manual Expert Log 800-900.doc21Operation of Writer / WriterWLUnitsFixed unitsPressure Bar mBar mWs PSI Pa

Pagina 15 - Configuration function s

ManualGB Manual Expert Log 800-900.doc22The Reader program (Reader)All recordings available in the device are listed by means of this program. Each re

Pagina 16 - Hysteresis

ManualGB Manual Expert Log 800-900.doc23InitializationBefore communications with the Expert Log can be established, the latter needs to be initialized

Pagina 17

ManualGB Manual Expert Log 800-900.doc24Modem:This page is needed for specification of a telephone number and additional initialization commands.Modem

Pagina 18

ManualGB Manual Expert Log 800-900.doc25If a mark is set, a new recording starts. This means that at the next read-out of the active recording(only No

Pagina 19

ManualGB Manual Expert Log 800-900.doc26Click Convert to compensate each file with the selected air pressure.Warning!No new files are created; instead

Pagina 20

ManualGB Manual Expert Log 800-900.doc27Creation of text data (Text-Converter)For display and/or further processing of measured values if required, co

Pagina 21

ManualGB Manual Expert Log 800-900.doc28Write only recorded channels into File:-The Data Logger was designed for recording 15 channels (at present a m

Pagina 22 - The Reader program (Reader)

ManualGB Manual Expert Log 800-900.doc29Sample file created using the Text-Converter, displayed in Microsoft Excel

Pagina 23

ManualGB Manual Expert Log 800-900.doc3Table of ContentsGeneral information...

Pagina 24 - Setting a mark

ManualGB Manual Expert Log 800-900.doc30Display module (Viewer)This module is used for displaying the measured values read out. The user can select th

Pagina 25

ManualGB Manual Expert Log 800-900.doc31Files with water level values:If a file with converted water level readings is displayed, in older versions of

Pagina 26

ManualGB Manual Expert Log 800-900.doc32WISKI-ConverterThe design of this module is very similar to that of the Text-Converter. It is also used for cr

Pagina 27

ManualGB Manual Expert Log 800-900.doc33Under "Options – Configuration - General" there are two selectable formats.ZRXP-Format:

Pagina 28

ManualGB Manual Expert Log 800-900.doc34Overstort-calculation (storm flow, Overflow calculation)In some countries (e.g. Holland, Belgium) water consu

Pagina 29

ManualGB Manual Expert Log 800-900.doc35APPENDIXSample applicationRecording configuration:Fixed Save-Interval = 1 hourEvent

Pagina 30 - Display module (Viewer)

ManualGB Manual Expert Log 800-900.doc36As soon as the configuration has been written into the device, a first measured value is recorded (inthe sampl

Pagina 31

ManualGB Manual Expert Log 800-900.doc37Messages:Message SignificanceREC-ERROR: P

Pagina 32 - WISKI-Converter

ManualGB Manual Expert Log 800-900.doc4Installation of Expert 900 LoggerGeneral informationFluid levels or fluctuations of a liquid can be determined

Pagina 33

ManualGB Manual Expert Log 800-900.doc5Absolute measurement (Expert 800)The Expert 800 instruments utilize an absolute pressure sensor. A secondExpert

Pagina 34 - Q = 1.7 x m x b x h

ManualGB Manual Expert Log 800-900.doc6Adapter ringSeeger circlipThe Expert 900 data loggers are lowered into the sinking pipe and fixed in position w

Pagina 35 - APPENDIX

ManualGB Manual Expert Log 800-900.doc7Replacing the batteryBattery: Sonnenschein 3.6V lithium AA typeThe Expert should be dried prior to opening to p

Pagina 36 - Pressure Conversion Table

ManualGB Manual Expert Log 800-900.doc8Dip pipe installationRevolution in level metrology:Gone are the days of the costly measuring stations at the la

Pagina 37 - Messages:

ManualGB Manual Expert Log 800-900.doc9Additional recommendations:- The battery capacity is not measured but calculated from the average current used.

Commenti su questo manuale