Enable: Checking the Enable box allows the display of the data for that channel in
the historical record. The pulse channels are always being monitored and the counts
between sampling intervals stored whether they are enabled or not.
Units: To enter a Sensor Name or Units, click on
the field and enter it or select from a list of units
predefined in the pull-down menu
Value for a Single Pulse: The number of pulses
is multiplied by this number to scale it to rainfall,
water flow, etc. If a pulse channel is connected to
a rain gauge that puts out a pulse every 1/100” of
rain, click on the field and enter 0.01 to display rainfall in Inches.
Decimal Places: This field determines how many places to the right of the decimal
point the data will be displayed in the main screen and historical data record. Select
the desired number of decimal places from the pull-down menu.